Hot Sell Long Service Life 5 Aluminum Alloy Blades Permanent Magnet Synchronous Motor Electric AC Industrial Ceiling HVLS Fans

Product Description

Product Showcase 1
Product Showcase 2
Product Details 1
Product Series W.Fans Series
Model W26 W24 W22 W20 W18 W16 W14 W12 WS10
Specification/ Diameter(m) 8 7.3 6.7 6.1 5.5 4.9 4.2 3.6 3.1
Speed (rpm) 10-45 10-55 10-60 10-60 10-70 10-75 10-80 10-90 10-100
Full-load air volume(m³/min) 17676 16130 14804 13800 12152 10826 9280 7954 6849
Coverage area(m²) 2462 2123 1809 1520 1256 1017 804 615 452
Rated power rate(kw) 1.5 1.1 0.75 0.4
Average consumption(kwh) ≤1.2 ≤1.0 ≤0.7 ≤0.4
Noise(dB) ≤38
Power supply (V) 380V/220S
Full-load current(A) 2.8(380V)/4.6(220V) 2.6(380V)/3.0(220V) 2.5 2.0
Weight(kg) 108 92 90 73 63 60 47 42 39
Feature 1 Feature 2 Feature 3
Feature 4 Feature 5 Feature 6
Series Overview
Production details 1 Production details 2 Production details 3
Certificates and standards
Frequently Asked Questions (FAQ)
Q1: What are the key benefits of installing W.Fans Series HVLS fans?
W.Fans Series HVLS (High Volume Low Speed) fans deliver massive airflow to cover large areas up to 2462m², effectively reducing perceived temperatures, improving indoor air quality, and reducing energy consumption compared to traditional HVAC systems.
Q2: How do I choose the correct fan model for my warehouse or workshop?
Choosing the right model depends on your facility's ceiling height and total coverage area. For instance, the W26 model offers a diameter of 8m and covers up to 2462m², while the WS10 model has a diameter of 3.1m covering 452m². Refer to our specifications table above for exact sizing parameters.
Q3: What are the electrical power supply requirements?
The W.Fans Series supports standard commercial power supplies, including 380V three-phase or 220V single-phase systems (380V/220S), making it adaptable to most industrial and commercial electrical grids.
Q4: Are these large industrial fans noisy during operation?
No. Despite their large dimensions, the W.Fans Series operates extremely quietly with noise levels kept at or below 38dB (≤38dB), ensuring a comfortable and distraction-free working environment.
Q5: What is the typical power consumption of these HVLS fans?
Our fans are designed for maximum energy efficiency. The average hourly consumption ranges from less than 0.4 kWh for smaller models (W12, WS10) to a maximum average of just 1.2 kWh for our largest W26 model.
Q6: What safety systems are integrated to prevent accidents?
Safety is paramount. The W.Fans Series features robust structural integration, reinforced steel safety cables, high-strength blade components, and anti-fall mechanisms to guarantee secure and reliable overhead operations.